Permit Info
Short Description:
1 BF FIRE PROT. 6397 AC, 8048 SF, SFR / 2 STORY
Status:
RES LETTER FINAL SENT
Expiration Date:
3/12/2018
Notes:
1 BF FIRE PROT. 6397 AC, 8048 SF, SFR / 2 STORY
10/30/2014 12:00:00 AM
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
014. BEAMS=10"W X 30"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
027. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
032. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
041. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
042. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
047. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
053. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF THIS ISSUED BUILDING PERMIT.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
(10/30/2014 9:21 AM JC)
Piers : 12" dia w/ belled (optional) to 36" dia. w/ vertical rebar per found. plan sch.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
NEWMAN VILLAGE PH ONE
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | ASHOUR, JAMIL & ABDO, MARIAM | ()- | | | FRISCO, TX 75034 |
MAIL TO | ASHOUR, JAMIL & ABDO, MARIAM | ()- | | | FRISCO, TX 75034 |
APPLICANT | PREMIER RENOVATIONS INC | (214)484-1448 | construction@rondaviscustomhomes.com | | DALLAS, TX 75252 |
CONTRACTOR | PREMIER RENOVATIONS INC | (214)484-1448 | construction@rondaviscustomhomes.com | | DALLAS, TX 75252 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | | ARLINGTON, TX 76094 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (214)708-7289 | rfrost@gsfireprotectionllc.com | 125 Richardson | ALLEN, TX 75002 |
HERS PROVIDE | BURGESS CONSTRUCTION CONSULTAN | (214)291-3141 | CBROOKS@BURGESS-INC.COM | | PLANO, TX 75075 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | kellyn.haughnout@resservices.com | | DALLAS, TX 75220 |
PLUM. CONT. | RAGSDALE PLUMBING | (903)450-4959 | RAGSDALEPLUMBINGINC@YAHOO.COM | | GREENVILLE, TX 75404 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | | | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
3/23/2015
|
BACK FLOW FORM REVIEW |
$25.00
|
6/22/2016
|
BACK FLOW FORM REVIEW |
$25.00
|
5/12/2017
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/9/2017
| | 5/9/2017 | |
More Info
|
BACKFLOW | APPROVED |
6/22/2016
| | 6/22/2016 | |
More Info
|
BACKFLOW | APPROVED |
3/12/2015
| | 3/12/2015 | |
More Info
|
There are currently no reviews on this record.