Permit Info
Short Description:
1 BF WTR SFTNR - 4335 AC, 5499 SF, SFR / 2 STORY
Expiration Date:
2/6/2019
Notes:
1 BF WTR SFTNR - 4335 AC, 5499 SF, SFR / 2 STORY
10/19/2011 12:00:00 AM
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
061. DOUBLE UNDERLAYMENT FELT REQUIRED FOR 4:12 PITCH ROOF OR LESS
2ND FLOOR: 3BR, 2BA, GAME, MEDIA, WETBAR, CARD ROOM
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
VILLAGES OF STONELAKE ESTATES #1C (CFR)
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | NALLAPAREDDY VAMSI KRISHNA & S | ()- | | | FRISCO, TX 75035-1208 |
MAIL TO | NALLAPAREDDY VAMSI KRISHNA & S | ()- | | | FRISCO, TX 75035-1208 |
APPLICANT | HIGHLAND HOMES | (972)789-3500 | cbagley@hhomesltd.com | 5601 DEMOCRACY DRIVE STE 300 | PLANO, TX 75024 |
CONTRACTOR | HIGHLAND HOMES | (972)789-3500 | cbagley@hhomesltd.com | 5601 DEMOCRACY DRIVE STE 300 | PLANO, TX 75024 |
ELECT. CTR. | FUSION ELECTRIC LLC | (972)347-2387 | FUSELEC@SBCGLOBAL.NET | P.O. BOX 936 | PROSPER, TX 75078 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)922-9000 | DLYONS@FOX-ENERGY.COM | 3109 LUBBOCK AVENUE | FORT WORTH, TX 76109 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76010 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | chernandez@lsplumb.com | | RICHARDSON, 75081 |
STRUCT ENG | ERIC L. DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
2/19/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
4/12/2017
|
CREDIT CARD FEE |
$0.50
|
4/12/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
2/8/2016
|
Total Fees |
Charged: $75.50
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
2/9/2018
| | 2/9/2018 | |
More Info
|
BACKFLOW | APPROVED |
4/11/2017
| | 4/11/2017 | |
More Info
|
BACKFLOW | APPROVED |
2/6/2016
| | 2/6/2016 | |
More Info
|
BACKFLOW | APPROVED |
2/11/2015
| | 2/11/2015 | |
More Info
|