Permit Info
Short Description:
1 BF WTR SFTNR - 4744 AC, 5902 SF, SFR / 2 STORY
Expiration Date:
6/28/2018
Notes:
1 BF WTR SFTNR - 4744 AC, 5902 SF, SFR / 2 STORY
7/17/2013 12:00:00 AM
001. COMPLIANCE WITH THE APRIL 5, 2011 ZONING ORDINANCE REQUIRED.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
VILLAGES OF STONELAKE ESTATES #5 (CFR)
|
BF TESTER | CHRIS JONES | (214)597-1760 | CJONES1004@VERIZON.NET | 1931 MIDDLE GLEN DR | CARROLLTON, TX 75007 |
OWNER | SHARMA SNIGDHA | ()- | | | FRISCO, TX 75035-0255 |
MAIL TO | SHARMA SNIGDHA | ()- | | 15080 DUBLIN LN | FRISCO, TX 75035 |
APPLICANT | SHADDOCK HOMES LTD | (972)398-4019 | lora@shaddockhomes.com | 2400 Dallas Parkway Suite 510 | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES LTD | (972)398-4019 | lora@shaddockhomes.com | 2400 Dallas Parkway Suite 510 | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | fstory@metrotechelectric.com | | WYLIE, TX 75098 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
7/31/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
11/10/2014
|
BACK FLOW FORM REVIEW |
$25.00
|
6/30/2016
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
7/24/2017
| | 7/24/2017 | |
More Info
|
BACKFLOW | APPROVED |
6/28/2016
| | 6/28/2016 | |
More Info
|
BACKFLOW | APPROVED |
11/10/2014
| | 11/10/2014 | |
More Info
|
There are currently no reviews on this record.