Permit Info
Short Description:
1 BF WTR SFTNR - 3839 AC, 4394 SF, SFR / 2 STORY
Expiration Date:
9/4/2018
Notes:
1 BF WTR SFTNR - 3839 AC, 4394 SF, SFR / 2 STORY
11/7/2013 12:00:00 AM
(11/7/2013 9:00 AM JC)
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH GRADES ARE REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
RIDGEVIEW AT PANTHER CREEK #1 (CFR)
|
BF TESTER | CHAD ADLER | (972)699-7156 | ADLERWATERWORKS@GMAIL.COM | 11305 KNOXVILLE LN | FRISCO, TX 75035 |
OWNER | KONDRAGANTI SRINIVASA & KRISHN | ()- | | | FRISCO, TX 75035-0235 |
MAIL TO | KONDRAGANTI SRINIVASA & KRISHN | ()- | | 12359 DEERBROOK DR | FRISCO, TX 75034 |
APPLICANT | FIRST TEXAS CUSTOM HOMES | (214)613-3400 | AGUTIERREZ@FIRSTTEXASHOMES.COM | | DALLAS, TX 75201 |
CONTRACTOR | FIRST TEXAS CUSTOM HOMES | (214)613-3400 | AGUTIERREZ@FIRSTTEXASHOMES.COM | | DALLAS, TX 75201 |
ELECT. CTR. | IES RESIDENTIAL INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | energy@metrocode.com | | FT WORTH, TX 76102 |
MECH. CTR. | STARN AIR INC | (214)221-1313 | STARNAIRINC@AOL.COM | | GARLAND, TX 75042 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | dthompson@lsmech.com | | RICHARDSON, 75081 |
STRUCT ENG | ERIC L DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
11/9/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
9/4/2014
|
BACK FLOW FORM REVIEW |
$25.00
|
11/17/2016
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
11/3/2017
| | 11/3/2017 | |
More Info
|
BACKFLOW | APPROVED |
11/17/2016
| | 11/17/2016 | |
More Info
|
BACKFLOW | APPROVED |
9/4/2014
| | 9/4/2014 | |
More Info
|
There are currently no reviews on this record.