1 BF FIRE PROT - 5174 AC, 6416 SF, SFR / 2 STORY
Expiration Date:
1/5/2019
Notes:
1 BF FIRE PROT - 5174 AC, 6416 SF, SFR / 2 STORY
11/11/2013 12:00:00 AM
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2ND FLOOR: 3BR, 2BA, GAME, MEDIA, EXERCISE, WETBAR, (1) SINK IN THE GARAGE WORK ROOM
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
WYNDSOR POINTE (CFR)
|
| BF TESTER | MARK KRAWIEC | (214)557-7686 | | 1310 N Creek Circle | WAXAHACHIE, TX 75165 |
| OWNER | DOLANSKI EDWARD P & SHELLEY E | ()- | | | FRISCO, TX 75034-1221 |
| MAIL TO | DOLANSKI EDWARD P & SHELLEY E | ()- | | 6590 GERRARD ST | FRISCO, TX 75034 |
| APPLICANT | LAGUNA HOMES | (214)415-4060 | LAGUNAHOMESINC@GMAIL.COM | | PLANO, TX 75024 |
| CONTRACTOR | LAGUNA HOMES | (214)415-4060 | LAGUNAHOMESINC@GMAIL.COM | | PLANO, TX 75024 |
| ELECT. CTR. | POTTER ELECTRIC | (972)442-1600 | claypottr@aol.com | | FARMERSVILLE, TX 75442 |
| FIRE CONTACT | URBAN FIRE PROTECTION | (972)289-4887 | | 222 S. TOWN EAST BLVD | MESQUITE, TX 75149 |
| HERS PROVIDE | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75082 |
| MECH. CTR. | AIRTRON INC | (972)272-9633 | kellyn.haughnout@resservices.com | | DALLAS, TX 75220 |
| PLUM. CONT. | INTERNATIONAL PLUMBING SERVICE | (214)938-7263 | DISHW@GMX.NET | | DALLAS, TX 75228 |
| STRUCT ENG | FOX ENERGY SPECIALIST | (817)922-9000 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
|
| BACK FLOW FORM REVIEW |
$25.00
|
1/11/2016
|
| BACK FLOW FORM REVIEW |
$25.00
|
1/27/2017
|
| BACK FLOW FORM REVIEW |
$25.00
|
1/15/2018
|
| BACK FLOW FORM REVIEW |
$25.00
|
7/28/2014
|
| Total Fees |
|
Charged: $100.00
Balance Due: $0.00
|
|
| BACKFLOW | APPROVED |
1/2/2018
| | 1/2/2018 | |
More Info
|
| BACKFLOW | APPROVED |
1/24/2017
| | 1/24/2017 | |
More Info
|
| BACKFLOW | APPROVED |
1/5/2016
| | 1/5/2016 | |
More Info
|
| BACKFLOW | APPROVED |
7/22/2014
| | 7/22/2014 | |
More Info
|