Permit Info
Short Description:
BF14-0086 5087 AC, 6617 SF, SFR / 2 STORY
Expiration Date:
9/24/2014
Notes:
BF14-0086 5087 AC, 6617 SF, SFR / 2 STORY
6/20/2013 12:00:00 AM
001. COMPLIANCE WITH THE APRIL 5, 2011 ZONING ORDINANCE REQUIRED.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER ENCLOSED SHEET (CZO PG 188).
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2ND FLOOR: 3BR, 3BA, GAME, MEDIA, WETBAR, BALCON
Parcel Info
City/State/Zip:
FRISCO, TX,
|
OWNER | HARKRIDER, JEREMY & STEPHANIE | ()- | | | FRISCO, TX 75034 |
MAIL TO | HARKRIDER, JEREMY & STEPHANIE | ()- | | | FRISCO, TX 75034 |
APPLICANT | BELCLAIRE HOMES | (972)410-5701 | | | THE COLONY, TX 75056 |
CONTRACTOR | BELCLAIRE HOMES | (972)410-5701 | | | THE COLONY, TX 75056 |
ELECT. CTR. | C & B ELECTRIC | (972)790-0707 | clindow@cbeltx.com | | GRAND PRAIRIE, TX 75050 |
FIRE CONTACT | RES COM FIRE SYSTEM | (214)350-1755 | | P O BOX 630886 | IRVING, TX 75063 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76010 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | | WYLIE, TX 75098 |
STRUCT ENG | ERIC L DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no inspections on this record.