Permit Info
Short Description:
1 BF FIRE PROT - 5609 AC, 6702 SF, SFR / 2 STORY
Expiration Date:
1/20/2019
Notes:
1 BF FIRE PROT - 5609 AC, 6702 SF, SFR / 2 STORY
2/12/2013 12:00:00 AM
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH GRADES ARE REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24".
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
059. INCLUDED IN THIS PERMIT PACK IS THE REQUIRED BARRIER-FREE RAMP; USE THE APPROPRIATE DETAIL FIGURE 1 OR 1a.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2nd FLOOR: 3-BED ROOMS, 3-BATHS, GAME, MEDIA AND FINISHED STORAGE ROOMS.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
PARK PLACE ESTATES PH1
|
BF TESTER | ISRAEL LAMBERT | (214)218-6415 | ISRAEL@LAMBERTSERVICESDFW.COM | 1417 ABILENE CT | ALLEN, TX 75013 |
OWNER | GOPAL, SOUNDARARAJAN & RAJARAM | ()- | Misty@shaddockhomes.com | | FRISCO, TX 75034 |
MAIL TO | GOPAL, SOUNDARARAJAN & RAJARAM | ()- | Misty@shaddockhomes.com | | FRISCO, TX 75034 |
APPLICANT | SHADDOCK HOMES LTD | (214)878-7810 | Misty@shaddockhomes.com | | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES LTD | (214)878-7810 | Misty@shaddockhomes.com | | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | fstory@metrotechelectric.com | | WYLIE, TX 75098 |
FIRE CONTACT | RES COM FIRE SYSTEM | (214)350-1755 | | P O BOX 630886 | IRVING, TX 75063 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/18/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
2/14/2018
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
2/7/2018
| | 2/7/2018 | |
More Info
|
BACKFLOW | APPROVED |
1/12/2017
| | 1/12/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/20/2016
| | 1/20/2016 | |
More Info
|
There are currently no reviews on this record.