Permit Info
Short Description:
1 BF FIRE PROT - 5100 AC, 6326 SF, SFR / 2 STORY
Approved Date:
12/15/2017
Expiration Date:
12/21/2018
Notes:
1 BF FIRE PROT - 5100 AC, 6326 SF, SFR / 2 STORY
1/14/2013 12:00:00 AM
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
027. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
028. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24".
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2-BED ROOMS, 3-BATHS GAME ROOM & UNFINISHED ATTIC-28X68 DOOR.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
NEWMAN VILLAGE PH ONE
|
BF TESTER | KYLE MIHALOVICH | ()- | | 600 HENRIETTA CREEK RD. | ROANOKE, TX 76262 |
OWNER | PELI, JAMES R & ANGELIA BLACKA | ()- | | | FRISCO, TX 75033 |
MAIL TO | PELI, JAMES R & ANGELIA BLACKA | ()- | | | FRISCO, TX 75033 |
APPLICANT | HENSLEY PREMIER HOMES | (972)668-1310 | | | FRISCO, TX 75033 |
CONTRACTOR | HENSLEY PREMIER HOMES | (972)668-1310 | | | FRISCO, TX 75033 |
ELECT. CTR. | SORENSON ELECTRIC | (972)578-9395 | SUSAN@SORENSENELECTRIC.COM | | PLANO, TX 75074 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | ALERT RESIDENTIAL INSPECTION P | (817)808-0274 | alertinspection@hotmail.com | 4101 W GREEN OAKS BLVD 305-203 | ARLINGTON, TX 76016 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)616-1100 | ahenson@reliantac.com | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | HORIZON PLUMBING | (817)461-1117 | JSANCHEZ@HORIZONPLUMBING.NET | | ARLINGTON, TX 76013 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
12/27/2016
|
BACK FLOW FORM REVIEW |
$25.00
|
12/28/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
12/15/2017
| | 12/15/2017 | |
More Info
|
BACKFLOW | APPROVED |
12/16/2016
| | 12/16/2016 | |
More Info
|
BACKFLOW | APPROVED |
12/21/2015
| | 12/21/2015 | |
More Info
|
There are currently no reviews on this record.