Permit Info
Short Description:
1 BF FIRE PROT - 6203 AC, 8804 SF, SFR / 2 STORY
Approved Date:
11/30/2017
Expiration Date:
12/12/2018
Notes:
1 BF FIRE PROT - 6203 AC, 8804 SF, SFR / 2 STORY
1/10/2013 12:00:00 AM
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
021. W/12" DIA. PIERS W/(2) #5 REBAR.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
028. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH GRADES ARE REQUIRED.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24".
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
NEWMAN VILLAGE PH ONE
|
BF TESTER | KOLTON HODGES | ()- | | 1224 BLACKHAWK DR | HASLET, TX 76057 |
OWNER | DIEHL, TROY & DINA | ()- | LARRYJSTONEII@GMAIL.COM | | FRISCO, TX 75033 |
MAIL TO | DIEHL, TROY & DINA | ()- | LARRYJSTONEII@GMAIL.COM | | FRISCO, TX 75033 |
APPLICANT | LARRY STONE CUSTOM HOMES | (972)849-3916 | LARRYJSTONEII@GMAIL.COM | | FRISCO, TX 75033 |
CONTRACTOR | LARRY STONE CUSTOM HOMES | (972)849-3916 | LARRYJSTONEII@GMAIL.COM | | FRISCO, TX 75033 |
ELECT. CTR. | BFB ELECTRICAL SERVICES | (469)231-7016 | ealvarado502@gmail.com | | GRAND PRAIRIE, TX 75051 |
FIRE CONTACT | RES COM FIRE SYSTEMS | (214)350-1755 | | P.O. BOX 630886 | IRVING, TX 75068 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | STAR POINT PLUMBING LLC | (214)618-3007 | JAVIER@STARPOITPLUMBING.COM | 9400 WADE BLVD #416 | FRISCO, TX 75035 |
STRUCT ENG | PARAGON STRUCTURAL ENGINEERING | (469)892-7520 | brian@pseglobal.com | | CARROLLTON, TX 75007 |
|
BACK FLOW FORM REVIEW |
$25.00
|
12/21/2016
|
BACK FLOW FORM REVIEW |
$25.00
|
12/6/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
11/30/2017
| | 11/30/2017 | |
More Info
|
BACKFLOW | APPROVED |
12/12/2016
| | 12/12/2016 | |
More Info
|
BACKFLOW | APPROVED |
12/21/2015
| | 12/21/2015 | |
More Info
|
There are currently no reviews on this record.