Permit Info
Short Description:
1 BF FIRE PROT - 6283 AC, 9372 SF, SFR / 2 STORY
Expiration Date:
2/6/2019
Notes:
1 BF FIRE PROT - 6283 AC, 9372 SF, SFR / 2 STORY
1/3/2014 12:00:00 AM
(1/3/2014 2:41 PM JC)
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
027. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
028. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
047. RISERS MUST BE 7 3/4" MAXIMUM; TREAD MINIMUM OF 10". LANDING AS REQUIRED BY 2006 IRC.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(1/3/2014 2:43 PM JC)
SLABTEK foundation system w/ 8" x 26" perimeter grade beams, 12" dia. piers w/ vertical rebar per plan sch.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
NEWMAN VILLAGE PH ONE
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | MEYER, COLIN & JESSICA | ()- | | | FRISCO, TX 75033 |
MAIL TO | MEYER, COLIN & JESSICA | ()- | | | FRISCO, TX 75033 |
APPLICANT | PREMIER RENOVATIONS INC | (972)618-3930 | RONDAVISCUSTOMHOMES@HOTMAIL.COM | | PLANO, TX 75025 |
CONTRACTOR | PREMIER RENOVATIONS INC | (972)618-3930 | RONDAVISCUSTOMHOMES@HOTMAIL.COM | | PLANO, TX 75025 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | | ARLINGTON, TX 76094 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (214)708-7289 | rfrost@gsfireprotectionllc.com | 125 Richardson | ALLEN, TX 75002 |
HERS PROVIDE | BURGESS CONSTRUCTION CONSULTAN | (214)291-3141 | CBROOKS@BURGESS-INC.COM | SUITE 1000 | PLANO, TX 75075 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | kellyn.haughnout@resservices.com | | DALLAS, TX 75220 |
PLUM. CONT. | RAGSDALE PLUMBING | (903)450-4959 | RAGSDALEPLUMBINGINC@YAHOO.COM | PO BOX 8647 | GREENVILLE, TX 75404 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
4/16/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
6/11/2014
|
BACK FLOW FORM REVIEW |
$25.00
|
5/9/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
2/8/2016
|
Total Fees |
Charged: $100.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
4/4/2018
| | 4/4/2018 | |
More Info
|
BACKFLOW | APPROVED |
4/13/2017
| | 4/13/2017 | |
More Info
|
BACKFLOW | APPROVED |
2/6/2016
| | 2/6/2016 | |
More Info
|
There are currently no reviews on this record.