Permit Info
Short Description:
2 BF FIRE PROT - 8455 AC, 11094 SF, SFR / 2 STORY
Approved Date:
12/12/2017
Expiration Date:
12/15/2018
Notes:
2 BF FIRE PROT - 8455 AC, 11094 SF, SFR / 2 STORY
5/13/2013 12:00:00 AM
(5/13/2013 8:38 AM JC)
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
027. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
028. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH GRADES ARE REQUIRED.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24".
047. RISERS MUST BE 7 3/4" MAXIMUM; TREAD MINIMUM OF 10". LANDING AS REQUIRED BY 2006 IRC.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
(5/13/2013 8:39 AM JC)
Piers : 12" dia w/ vert. rebar per plan sch.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STARWOOD #4 VILLAGE #17 (CFR)
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | SOHAIL OMER & | ()- | | ZAINAB ELLAM | FRISCO, TX 75034-4078 |
MAIL TO | SOHAIL OMER & ZAINAB ELLAM | ()- | | 5477 MONTEREY | FRISCO, TX 75034 |
APPLICANT | AVIDA CUSTOM HOMES | (972)740-8900 | | P.O. BOX 802611 | DALLAS, TX 75380 |
CONTRACTOR | AVIDA CUSTOM HOMES | (972)740-8900 | | P.O. BOX 802611 | DALLAS, TX 75380 |
ELECT. CTR. | PUCKETT ELECTRIC | (972)864-0020 | PUCKETTELEC@YAHOO.COM | | GARLAND, TX 75041 |
FIRE CONTACT | RES COM FIRE SYSTEM | (214)350-1755 | | P O BOX 630886 | IRVING, TX 75063 |
MECH. CTR. | CHAPMAN AIR & HEAT | (214)340-4999 | ascutter@chapmanair.com | | DALLAS, TX 75238 |
PLUM. CONT. | RRC PLUMBING LLC | (972)569-9997 | RRCONF97@SBCGLOBAL.NET | | MCKINNEY, TX 75070 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$50.00
|
12/28/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
1/6/2017
|
CREDIT CARD FEE |
$0.50
|
1/6/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
4/14/2017
|
Total Fees |
Charged: $100.50
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
12/12/2017
| | 12/12/2017 | |
More Info
|
BACKFLOW | APPROVED |
12/12/2017
| | 12/12/2017 | |
More Info
|
BACKFLOW | APPROVED |
4/13/2017
| | 4/13/2017 | |
More Info
|
BACKFLOW | APPROVED |
12/15/2016
| | 12/15/2016 | |
More Info
|
BACKFLOW | APPROVED |
12/31/2015
| | 12/31/2015 | |
More Info
|
BACKFLOW | APPROVED |
12/31/2015
| | 12/31/2015 | |
More Info
|
BACKFLOW | APPROVED |
8/26/2014
| | 8/26/2014 | |
More Info
|
BACKFLOW | APPROVED |
8/19/2014
| | 8/19/2014 | |
More Info
|
There are currently no reviews on this record.