Permit Info
Short Description:
1 BF FIRE PROT - 5757 AC, 7116 SF, SFR / 2 STORY
Expiration Date:
2/12/2019
Notes:
1 BF FIRE PROT - 5757 AC, 7116 SF, SFR / 2 STORY
12/11/2012 12:00:00 AM
001. COMPLIANCE WITH THE APRIL 5, 2011 ZONING ORDINANCE REQUIRED.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
012. BEAMS=10"W X 30"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH GRADES ARE REQUIRED.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24".
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
051. WINDOW BOX-OUTS WITH SIDING & TRIM MUST NOT EXCEED TWICE THE WINDOW M.O. AREA.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER ENCLOSED SHEET (CZO PG 188).
059. INCLUDED IN THIS PERMIT PACK IS THE REQUIRED BARRIER-FREE RAMP; USE THE APPROPRIATE DETAIL FIGURE 1 OR 1a.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
RICHWOODS #4 (CFR)
|
BF TESTER | SANJAY CHANDRAHAS | (214)738-5657 | | 2031 CACISEO WAY | ALLEN, TX 75013 |
OWNER | VATTAM SREENADHA R & SUREKHA M | ()- | CRUSSELL@LANDONHOMESUSA.COM | | FRISCO, TX 75035-7216 |
MAIL TO | VATTAM SREENADHA R & SUREKHA M | ()- | CRUSSELL@LANDONHOMESUSA.COM | | FRISCO, TX 75035-7216 |
APPLICANT | LANDON HOMES | (214)619-1077 | CRUSSELL@LANDONHOMESUSA.COM | | PLANO, TX 75093 |
CONTRACTOR | LANDON HOMES | (214)619-1077 | CRUSSELL@LANDONHOMESUSA.COM | | PLANO, TX 75093 |
ELECT. CTR. | IES RESIDENTIAL, INC | (972)562-7724 | brian.hartley@ies-co.com | SUITE A | MCKINNEY, TX 75069 |
FIRE CONTACT | RES COM FIRE SYSTEM | (214)350-1755 | | P O BOX 630886 | IRVING, TX 75063 |
HERS PROVIDE | ENERGY CODE SOLUTIONS | (817)412-0351 | ENERGYINSPECT@ATT.NET | | EULESS, TX 76040 |
MECH. CTR. | AIRTRON INC | (214)355-1232 | SHARON.JOHNSON@RESSERVICES.COM | | DALLAS, TX 75243 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | dgugliotta@lsplumb.com | SUITE 210 | RICHARDSON, 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/19/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
3/1/2018
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
3/1/2018
| | 3/1/2018 | |
More Info
|
BACKFLOW | APPROVED |
6/16/2017
| | 6/16/2017 | |
More Info
|
BACKFLOW | APPROVED |
2/12/2016
| | 2/12/2016 | |
More Info
|
There are currently no reviews on this record.