Permit Info
Short Description:
1 BF FIRE PROT - SEE NOTES 5739 AC, 7286 SF, SFR / 2 STORY
Expiration Date:
11/2/2013
Notes:
1 BF FIRE PROT - SEE NOTES 5739 AC, 7286 SF, SFR / 2 STORY
7/9/2012 12:00:00 AM
001. COMPLIANCE WITH THE APRIL 5, 2011 ZONING ORDINANCE REQUIRED.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
055. FUEL BURNING APPLIANCE INSTALLATION MUST BE CODE COMPLIANT.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. DRIVEWAY ENHANCEMENT & GARAGE DOOR TREATMENT PER ATTACHED INSTRUCTIONS.
(02/16/2016 9:47 AM LHG)
WET SYSTEM FOR FIRE. NO BF, PER BUILDER.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
RICHWOODS #4 (CFR)
|
OWNER | MEDINA JOSE CARLOS & DORENE GR | ()- | CRUSSELL@LANDONHOMESUSA.COM | | FRISCO, TX 75035-7220 |
MAIL TO | MEDINA JOSE CARLOS & DORENE GR | ()- | CRUSSELL@LANDONHOMESUSA.COM | | FRISCO, TX 75035-7220 |
APPLICANT | LANDON HOMES | (214)619-2930 | CRUSSELL@LANDONHOMESUSA.COM | | PLANO, TX 75093 |
CONTRACTOR | LANDON HOMES | (214)619-2930 | CRUSSELL@LANDONHOMESUSA.COM | | PLANO, TX 75093 |
ELECT. CTR. | IES RESIDENTIAL, INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
HERS PROVIDE | ENERGY CODE SOLUTIONS | (817)412-0351 | ENERGYINSPECT@ATT.NET | | EULESS, TX 76040 |
MECH. CTR. | PRO STAR AIR | (972)245-0700 | RANDY@PROSTARAIR.COM | 1225 E CROSBY RD #A-21 | CARROLLTON, TX 75006 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no inspections on this record.
There are currently no reviews on this record.