Permit Info
Short Description:
1 BF FIRE PROT - 5922 AC, 7301 SF, SFR / 2 STORY
Status:
RES LETTER FINAL SENT
Approved Date:
12/14/2016
Expiration Date:
12/14/2017
Notes:
1 BF FIRE PROT - 5922 AC, 7301 SF, SFR / 2 STORY
5/9/2012 12:00:00 AM
001. COMPLIANCE WITH THE APRIL 5, 2011 ZONING ORDINANCE REQUIRED.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
SHADDOCK CREEK ESTATES PH 5
|
BF TESTER | BRIAN L. HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | MURRAY, ROBERT MATTHEW & PAMEL | ()- | STEPHANIE@SHADDOCKHOMES.COM | | FRISCO, TX 75033 |
MAIL TO | MURRAY, ROBERT MATTHEW & PAMEL | ()- | STEPHANIE@SHADDOCKHOMES.COM | | FRISCO, TX 75033 |
APPLICANT | SHADDOCK HOMES, LTD | (469)241-9581 | STEPHANIE@SHADDOCKHOMES.COM | | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES, LTD | (469)241-9581 | STEPHANIE@SHADDOCKHOMES.COM | | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | wstory@metrotechelectric.com | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
FIRE CONTACT | RES COM FIRE SYSTEMS | (214)350-1755 | | P.O. BOX 630886 | IRVING, TX 75068 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
12/14/2016
| | 12/14/2016 | |
More Info
|
There are currently no reviews on this record.