(3/2/2012 8:27 AM JC)
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(3/2/2012 8:27 AM JC)
(MFD)
1 BF FIRE PROT - 6054 AC, 7331 SF, SFR / 2 STORY
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
SHADDOCK CREEK ESTATES PH 5
|
BF TESTER | ISRAEL LAMBERT | (214)218-6415 | ISRAEL@LAMBERTSERVICESDFW.COM | 1417 ABILENE CT | ALLEN, TX 75013 |
OWNER | VANATTA, KIMBERLY A | ()- | STEPHANIE@SHADDOCKHOMES.COM | | FRISCO, TX 75033 |
MAIL TO | VANATTA, KIMBERLY A | ()- | STEPHANIE@SHADDOCKHOMES.COM | | FRISCO, TX 75033 |
APPLICANT | SHADDOCK HOMES, LTD | (469)241-9581 | STEPHANIE@SHADDOCKHOMES.COM | | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES, LTD | (469)241-9581 | STEPHANIE@SHADDOCKHOMES.COM | | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | wstory@metrotechelectric.com | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
FIRE CONT 2 | Rescom Fire Systems | (214)538-7500 | | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/26/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/22/2017
| | 5/22/2017 | |
More Info
|
There are currently no reviews on this record.