Permit Info
Short Description:
1 BF FIRE PROT - 7887 AC, 9663 SF, SFR / 2 STORY
Status:
RES LETTER FINAL SENT
Expiration Date:
1/8/2014
Notes:
1 BF FIRE PROT - 7887 AC, 9663 SF, SFR / 2 STORY
4/17/2012 12:00:00 AM
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
012. BEAMS=10"W X 30"D.
022. W/12" DIA. PIERS W/(3) #5 REBAR.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
047. RISERS MUST BE 7 3/4" MAXIMUM; TREAD MINIMUM OF 10". LANDING AS REQUIRED BY 2006 IRC.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(12/27/2016 12:07 PM BJS)
OWNER CALLED WILL HAVE DO BY JAN 31-2017 OK BY BILLY S
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STARWOOD #4 VILLAGE NO. 16 (CFR)
|
OWNER | DALEY TREVOR | ()- | wlewis@andrewmerrick.com | | FRISCO, TX 75034-2252 |
MAIL TO | DALEY TREVOR | ()- | wlewis@andrewmerrick.com | | FRISCO, TX 75034-2252 |
APPLICANT | ANDREW MERRICK COMPANIES LLC | (972)839-7274 | wlewis@andrewmerrick.com | | FRISCO, TX 75034 |
CONTRACTOR | ANDREW MERRICK COMPANIES LLC | (972)839-7274 | wlewis@andrewmerrick.com | | FRISCO, TX 75034 |
ELECT. CTR. | ARI-TEX ELECTRIC INC | (972)727-9902 | | | ALLEN, TX 75013 |
FIRE CONT 2 | Davis Fire Systems | ()- | | 11022 old Military | FORNEY, TX 75126 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)922-9000 | DLYONS@FOX-ENERGY.COM | 3109 LUBBOCK AVENUE | FORT WORTH, TX 76109 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76010 |
PLUM. CONT. | TEXAS PLUMB MECHANICAL | (972)210-9100 | TYSA_B_TXPLM@YAHOO.COM | | LEWISVILLE, TX 75057 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.