Permit Info
Short Description:
1 BF, WTR SFTNR, 1 FIRE - 5057 AC, 6680 SF, SFR / 2 STORY
Status:
RES LETTER TWO SENT
Expiration Date:
4/9/2018
Notes:
1 BF, WTR SFTNR, 1 FIRE - 5057 AC, 6680 SF, SFR / 2 STORY
12/11/2013 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
VILLAGES OF STONELAKE ESTATES #5 (CFR)
|
| BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
| OWNER | CORREA GABRIEL T & SANDRA | ()- | | | FRISCO, TX 75035-0274 |
| MAIL TO | CORREA GABRIEL T & SANDRA | ()- | | | FRISCO, TX 75035-0274 |
| APPLICANT | SHADDOCK HOMES LTD | (972)398-4019 | lora@shaddockhomes.com | | PLANO, TX 75093 |
| CONTRACTOR | SHADDOCK HOMES LTD | (972)398-4019 | lora@shaddockhomes.com | | PLANO, TX 75093 |
| ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | fstory@metrotechelectric.com | | WYLIE, TX 75098 |
| FIRE CONTACT | RES COM FIRE SYSTEM | (214)350-1755 | | P O BOX 630886 | IRVING, TX 75063 |
| HERS PROVIDE | STRAND SYSTEMS ENGINEERING | (972)620-8204 | jennifer@strandsystems.com | | IRVING, TX 75039 |
| MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
| PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
| STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75082 |
|
| BACK FLOW FORM REVIEW |
$50.00
|
5/22/2017
|
| BACK FLOW FORM REVIEW |
$25.00
|
6/2/2014
|
| Total Fees |
|
Charged: $75.00
Balance Due: $0.00
|
|
| BACKFLOW | APPROVED |
5/19/2017
| | 5/19/2017 | |
More Info
|
| BACKFLOW | APPROVED |
5/19/2017
| | 5/19/2017 | |
More Info
|
| BACKFLOW | APPROVED |
4/4/2016
| | 4/4/2016 | |
More Info
|
| BACKFLOW | APPROVED |
4/4/2016
| | 4/4/2016 | |
More Info
|
| BACKFLOW | APPROVED |
8/8/2014
| | 8/8/2014 | |
More Info
|
| BACKFLOW | APPROVED |
5/30/2014
| | 5/30/2014 | |
More Info
|
There are currently no reviews on this record.