Permit Info
Short Description:
1 BF FIRE PROT - 5567 AC, 6421 SF, SFR / 2 STORY
Expiration Date:
2/19/2019
Notes:
1 BF FIRE PROT - 5567 AC, 6421 SF, SFR / 2 STORY
6/26/2013 12:00:00 AM
001. COMPLIANCE WITH THE APRIL 5, 2011 ZONING ORDINANCE REQUIRED.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
012. BEAMS=10"W X 30"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
023. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER ENCLOSED SHEET (CZO PG 188).
059. INCLUDED IN THIS PERMIT PACK IS THE REQUIRED BARRIER-FREE RAMP; USE THE APPROPRIATE DETAIL FIGURE 1 OR 1a.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
THE SHORES AT WATERSTONE PHASE 2
|
BF TESTER | BRIAN L. HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | SUMPON, GOLDA | ()- | michelle.rae@meritagehomes.com | | FRISCO, TX 75034 |
MAIL TO | SUMPON, GOLDA | ()- | michelle.rae@meritagehomes.com | | FRISCO, TX 75034 |
APPLICANT | MERITAGE HOMES | (972)580-6300 | michelle.rae@meritagehomes.com | 909 Hidden Ridge #190 | IRVING, TX 75038 |
CONTRACTOR | MERITAGE HOMES | (972)580-6300 | michelle.rae@meritagehomes.com | 909 Hidden Ridge #190 | IRVING, TX 75038 |
ELECT. CTR. | C & B ELECTRIC | (972)790-0707 | clindow@cbeltx.com | | GRAND PRAIRIE, TX 75050 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | BURGESS CONSTRUCTION CONSULTAN | (214)291-3141 | CBROOKS@BURGESS-INC.COM | SUITE 1000 | PLANO, TX 75075 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | kellyn.haughnout@resservices.com | | DALLAS, TX 75220 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | dthompson@lsmech.com | | RICHARDSON, 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/26/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
3/14/2018
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
3/8/2018
| | 3/8/2018 | |
More Info
|
BACKFLOW | APPROVED |
6/14/2017
| | 6/14/2017 | |
More Info
|
BACKFLOW | APPROVED |
2/19/2016
| | 2/19/2016 | |
More Info
|
BACKFLOW | APPROVED |
3/24/2014
| | 3/24/2014 | |
More Info
|
There are currently no reviews on this record.