Permit Info
Short Description:
1 BF FIRE PROT - 5296 AC, 6405 SF, SFR / 2 STORY
Approved Date:
12/15/2017
Expiration Date:
1/4/2019
Notes:
1 BF FIRE PROT - 5296 AC, 6405 SF, SFR / 2 STORY
7/23/2013 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER ENCLOSED SHEET (CZO PG 188).
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
Parcel Info
City/State/Zip:
FRISCO, TX,
|
BF TESTER | KYLE MIHALOVICH | ()- | | 600 HENRIETTA CREEK RD. | ROANOKE, TX 76262 |
OWNER | ROYER, JUSTIN T | ()- | dtanguay@hhomesltd.com | | FRISCO, TX 75034 |
MAIL TO | ROYER, JUSTIN T | ()- | dtanguay@hhomesltd.com | | FRISCO, TX 75034 |
APPLICANT | HUNTINGTON HOMES | (972)789-3500 | dtanguay@hhomesltd.com | SUITE 300 | FRISCO, TX 75035 |
CONTRACTOR | HUNTINGTON HOMES | (972)789-3500 | dtanguay@hhomesltd.com | SUITE 300 | FRISCO, TX 75035 |
ELECT. CTR. | IN CHARGE ELECTRICAL SERVICES | (512)778-6240 | SETHROBINSON@IN-CHARGE-ELECTIC.COM | SUITE 303 | FRISCO, TX 75034 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | ()- | | 906 W MCDERMOTT #116 | ALLEN, TX |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)922-9000 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76010 |
PLUM. CONT. | LASITER & LASITER PLUMBING | (817)831-4245 | SHANNONB@LASITER.COM | 6307 MIDWAY RD | HALTOM CITY, TX 76117 |
STRUCT ENG | ERIC L DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/10/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
12/28/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
12/2/2013
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
12/15/2017
| | 12/15/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/4/2017
| | 1/4/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/7/2016
| | 1/7/2016 | |
More Info
|