Permit Info
Short Description:
1 BF WTR SFTNR - 4045 AC, 5035 SF, SFR / 2 STORY
Expiration Date:
6/1/2018
Notes:
1 BF WTR SFTNR - 4045 AC, 5035 SF, SFR / 2 STORY
10/26/2012 12:00:00 AM
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24".
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
(10/26/2012 3:15 PM JC)
2nd. story w/ (4) bedrooms, (2) baths, gm. & media.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
SORANO (CFR)
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | POLAVARAPU RAJESH & RANJITHA N | ()- | AGUTIERREZ@FIRSTTEXASHOMES.COM | | FRISCO, TX 75035-9275 |
MAIL TO | POLAVARAPU RAJESH & RANJITHA N | ()- | AGUTIERREZ@FIRSTTEXASHOMES.COM | | FRISCO, TX 75035-9275 |
APPLICANT | FIRST TEXAS CUSTOM HOMES | (214)613-3400 | AGUTIERREZ@FIRSTTEXASHOMES.COM | SUITE 500 | DALLAS, TX 75201 |
CONTRACTOR | FIRST TEXAS CUSTOM HOMES | (214)613-3400 | AGUTIERREZ@FIRSTTEXASHOMES.COM | SUITE 500 | DALLAS, TX 75201 |
ELECT. CTR. | IES RESIDENTIAL, INC | (972)562-7724 | brian.hartley@ies-co.com | SUITE A | MCKINNEY, TX 75069 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | energy@metrocode.com | | FT WORTH, TX 76102 |
MECH. CTR. | STARN AIR INC | (214)221-1313 | STARNAIRINC@AOL.COM | | GARLAND, TX 75042 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | dgugliotta@lsplumb.com | SUITE 210 | RICHARDSON, 75081 |
STRUCT ENG | ERIC L DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/23/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
8/7/2013
|
BACK FLOW FORM REVIEW |
$25.00
|
6/10/2016
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
6/10/2017
| | 6/10/2017 | |
More Info
|
BACKFLOW | APPROVED |
6/1/2016
| | 6/1/2016 | |
More Info
|
BACKFLOW | APPROVED |
7/31/2013
| | 7/31/2013 | |
More Info
|
There are currently no reviews on this record.