Permit Info
Short Description:
1 BF FIRE PROT 6043 AC, 8560 SF, SFR / 2 STORY
Status:
RES LETTER FINAL SENT
Expiration Date:
6/19/2013
Notes:
1 BF FIRE PROT 6043 AC, 8560 SF, SFR / 2 STORY
2/21/2012 12:00:00 AM
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
(2/21/2012 4:24 PM JC)
Grade Beams : 12" x 34" ext., 10" x 34" int.
2nd. story w/ (3) bedrooms, (3) baths, game, media rooms & covered balcony.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
NEWMAN VILLAGE PH ONE
|
BF TESTER | DAGOBERTO HERNANDEZ | (214)717-1011 | | 1426 RIDGECREST DR. | PLANO, TX 75074 |
OWNER | NEWBERRY, KARIN JOLE & SAMUEL | ()- | | | FRISCO, TX 75033-2885 |
MAIL TO | NEWBERRY, KARIN JOLE & SAMUEL | ()- | | | FRISCO, TX 75033-2885 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | PO BOX 13338 | ARLINGTON, TX 76094 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (877)871-1703 | | 125 RICHARDSON CT #150 | ALLEN, TX 75002 |
HERS PROVIDE | BURGESS CONSTRUCTION CONSULTAN | (214)291-3141 | CBROOKS@BURGESS-INC.COM | 1255 W 15TH STE 100 | PLANO, TX 75075 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | SHARON.JOHNSON@RESSERVICES.COM | | DALLAS, TX 75243 |
PLUM. CONT. | RAGSDALE PLUMBING | (903)450-4959 | RAGSDALEPLUMBINGINC@YAHOO.COM | PO BOX 8647 | GREENVILLE, TX 75404 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/19/2012
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
6/19/2012
| | 6/19/2012 | |
More Info
|
There are currently no reviews on this record.