Permit Info
Short Description:
1 bf fire prot 5557 AC, 7235 SF, SFR / 2 STORY
Status:
RES LETTER ONE SENT
Expiration Date:
5/4/2018
Notes:
1 bf fire prot 5557 AC, 7235 SF, SFR / 2 STORY
2/1/2012 12:00:00 AM
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
027. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(2/1/2012 9:28 AM JC)
Grade Beams : 12" x 34" ext., 10" x 34" int. w/ 12" dia piers w/ vert. rebar per sch.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
NEWMAN VILLAGE PH ONE
|
BF TESTER | SANJAY CHANDRAHAS | (214)738-5657 | | 2031 CACISEO WAY | ALLEN, TX 75013 |
OWNER | MILAM, STEVEN & BARBARA | ()- | | | FRISCO, TX 75033 |
MAIL TO | MILAM, STEVEN & BARBARA | ()- | RONDAVISCUSTOMHOMES@HOTMAIL.COM | | DALLAS, TX 75234 |
APPLICANT | PREMIER RENOVATIONS INC | (972)618-3930 | RONDAVISCUSTOMHOMES@HOTMAIL.COM | | PLANO, TX 75025 |
CONTRACTOR | PREMIER RENOVATIONS INC | (972)618-3930 | RONDAVISCUSTOMHOMES@HOTMAIL.COM | | PLANO, TX 75025 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | PO BOX 13338 | ARLINGTON, TX 76094 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (877)871-1703 | | 125 RICHARDSON CT | ALLEN, TX 75002 |
HERS PROVIDE | BURGESS CONSTRUCTION CONSULTAN | (214)291-3141 | CBROOKS@BURGESS-INC.COM | 1255 W 15TH STE 100 | PLANO, TX 75075 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | SHARON.JOHNSON@RESSERVICES.COM | | DALLAS, TX 75243 |
PLUM. CONT. | RAGSDALE PLUMBING | (903)450-4951 | | PO BOX 8647 | GREENVILLE, TX 75404 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/15/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
5/14/2012
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
6/15/2017
| | 6/15/2017 | |
More Info
|
BACKFLOW | APPROVED |
5/4/2012
| | 5/4/2012 | |
More Info
|
There are currently no reviews on this record.