Permit Info
Short Description:
1 FIRE PROT-5314 AC, 6591 SF, SFR / 2 STORY
Expiration Date:
4/22/2019
Notes:
1 FIRE PROT-5314 AC, 6591 SF, SFR / 2 STORY
12/19/2011 12:00:00 AM
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
047. RISERS MUST BE 7 3/4" MAXIMUM; TREAD MINIMUM OF 10". LANDING AS REQUIRED BY 2006 IRC.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(12/19/2011 1:34 PM JC)
2nd. story w/ (3) bedrooms, (2) baths, combined media & game rooms.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
SHADDOCK CREEK ESTATES PH 5
|
BF TESTER | TRAVIS CANTRELL | (817)222-1283 | tcantrell@idealpartnerstx.com | 6913 CAMP BOWIE BLVD #181 | FORT WORTH, TX 76116 |
OWNER | BISHOP, JOHN S & NANCY J | ()- | SHELLY@REYNOLDSSIGNATUREHOMES.COM | | FRISCO, TX 75033 |
MAIL TO | BISHOP, JOHN S & NANCY J | ()- | SHELLY@REYNOLDSSIGNATUREHOMES.COM | | FRISCO, TX 75033 |
APPLICANT | REYNOLDS SIGNATURE HOMES | (972)712-6732 | SHELLY@REYNOLDSSIGNATUREHOMES.COM | P O BOX 2131 | Frisco, Tx 75034 |
CONTRACTOR | REYNOLDS SIGNATURE HOMES | (972)712-6732 | SHELLY@REYNOLDSSIGNATUREHOMES.COM | P O BOX 2131 | Frisco, Tx 75034 |
ELECT. CTR. | GALAXY ELECTRIC INC | (469)682-1375 | | 309 N GALLOWAY | MESQUITE, TX 75149 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | TRUE HOME ENERGY SOLUTIONS | (972)575-8320 | carls@truehomeenergysolutions.com | PO BOX 2644 | WYLIE, TX 75098 |
MECH. CTR. | TEMPO MECHANICAL SERVICES | (972)579-2000 | david.gannon@tempoair.com | 2611 E PIONEER DR | IRVING, TX 75061 |
PLUM. CONT. | RRC PLUMBING, LLC | (972)569-9997 | RRCONF97@SBCGLOBAL.NET | 601 ISLEWORTH LANE | MCKINNEY, TX 75070 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
4/29/2016
|
BACK FLOW FORM REVIEW |
$25.00
|
5/17/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
5/14/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
4/5/2012
|
Total Fees |
Charged: $100.00
Balance Due: $0.00
|
There are currently no reviews on this record.