Permit Info
Short Description:
1 fire bf 8518 AC, 11077 SF, SFR / 2 STORY
Expiration Date:
12/6/2018
Notes:
1 fire bf 8518 AC, 11077 SF, SFR / 2 STORY
9/17/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
006. BEAMS=8"W X 28"D.
022. W/12" DIA. PIERS W/(3) #5 REBAR. (OR AS ON S2)
027. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
2nd FLOOR: 3-BED ROOMS, 3-BATHS,COMPUTER ALCOVE, PLAY ROOM & COVERED BALCONY.
THIS PERMIT IS BEING HELD UNTIL COMPLETE PLOT PLAN INFORMATION IS RECEIVED AS REQUIRED IN E-MAIL TODAY.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STARWOOD #4 VILLAGE #17 (CFR)
|
BF TESTER | BRIAN HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | WEBB JAMES HAROLD JR LIVING TR | ()- | LOY@VENTURACUSTOMHOMES.COM | JAMES HAROLD WEBB JR - TRUSTEE | FRISCO, TX 75034-4091 |
MAIL TO | WEBB JAMES HAROLD JR LIVING TR | ()- | LOY@VENTURACUSTOMHOMES.COM | | FRISCO, TX 75034-4091 |
APPLICANT | VCH HOLDINGS | (972)335-5233 | LOY@VENTURACUSTOMHOMES.COM | 17814 DAVENPORT DRIVE SUITE 1 | DALLAS, TX 75252 |
CONTRACTOR | VCH HOLDINGS | (972)335-5233 | LOY@VENTURACUSTOMHOMES.COM | 17814 DAVENPORT DRIVE SUITE 1 | DALLAS, TX 75252 |
ELECT. CTR. | ROMAN ELECTRIC | (469)995-0634 | ROMAN.ELECTRIC@YAHOO.COM | 1316 ACOSTA | GRAND PRAIRIE, TX 75052 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | KRUGER & SON HEATING & AIR | (972)271-9319 | | 2166 S JUPITER | GARLAND, TX 75041 |
PLUM. CONT. | RIDDELL PLUMBING, INC. | (972)682-4860 | SCOTT@RIDDELLPLUMBING.COM | 3700 US HIGHWAY 80 EAST | MESQUITE, TX 75149 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
8/15/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
12/14/2011
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|