Permit Info
Short Description:
3634 AC, 4665 SF, SFR / 2 STORY
Notes:
3634 AC, 4665 SF, SFR / 2 STORY
6/3/2011 12:00:00 AM
(6/3/2011 3:03 PM JC)
001. ENERGY STAR/GREEN BLDG/90 DAY DIRECTIVE EFF 04/01/2011.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
015. BEAMS=12"W X 24"D.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
028. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
(6/3/2011 3:04 PM JC)
2nd. story with (1) bedroom, (1) bath.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
NEWMAN VILLAGE PH ONE
|
BF TESTER | PATRICK RYAN | (972)689-2088 | | NORTH TEXAS LAWN & LANDSCAPE | ROCKWALL, TX 75087 |
OWNER | M CHRISTOPHER CUSTOM HOMES | (214)675-9229 | DAN@MCHRISTOPHERANDCOMPANY.COM | 630 OAKMONT CT | FAIRVIEW, TX 75069 |
APPLICANT | M CHRISTOPHER CUSTOM HOMES | (214)675-9229 | DAN@MCHRISTOPHERANDCOMPANY.COM | 630 OAKMONT CT | FAIRVIEW, TX 75069 |
CONTRACTOR | M CHRISTOPHER CUSTOM HOMES | (214)675-9229 | DAN@MCHRISTOPHERANDCOMPANY.COM | 630 OAKMONT CT | FAIRVIEW, TX 75069 |
ELECT. CTR. | IES RESIDENTIAL, INC | (972)562-7724 | BECKY.COLLIER@IES-CO.COM | 713 TOWER LANE SUITE A | MCKINNEY, TX 75069 |
HERS PROVIDE | TEX ENERGY SOLUTIONS | (972)579-2009 | mendozam@texenergy.org | 2611 E PIONEER DR | IRVING, TX 75061 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)831-3950 | dripley@reliantac.com | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | RANGER PLUMBING LLC | (214)585-6632 | D2HILT@HOTMAIL.COM | 5209 BOBTOWN ROAD | GARLAND, TX 75043 |
STRUCT ENG | NORTEX FOUNDATION DESIGNS | (817)379-0866 | info@nortexfoundation.com | 4416 KELLER HICKS RD | FORT WORTH, TX 76244 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/21/2011
| | 10/21/2011 | |
More Info
|
There are currently no reviews on this record.