Permit Info
Short Description:
1 BF FIRE PROT - 5094 AC, 6266 SF, SFR / 2 STORY
Approved Date:
10/17/2017
Expiration Date:
10/17/2018
Notes:
1 BF FIRE PROT - 5094 AC, 6266 SF, SFR / 2 STORY
12/30/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
027. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
028. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
034. EXTERIOR TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
2nd FLOOR: 3-BED ROOM, 3-BATHS, GAME, 2nd UTILITY ROOM AND COVERED BALCONY.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
SHADDOCK CREEK ESTATES PH 5
|
BF TESTER | BRIAN HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | TUMMALA, PRATAP R & HIMABINDU | ()- | bhensley@hensleypremierbuilders.com | | FRISCO, TX 75033 |
MAIL TO | TUMMALA, PRATAP R & HIMABINDU | ()- | bhensley@hensleypremierbuilders.com | | FRISCO, TX 75033 |
APPLICANT | HENSLEY PREMIER BUILDERS | (972)608-1310 | bhensley@hensleypremierbuilders.com | 1090 COLLETON LN | FRISCO, TX 75034 |
CONTRACTOR | HENSLEY PREMIER BUILDERS | (972)608-1310 | bhensley@hensleypremierbuilders.com | 1090 COLLETON LN | FRISCO, TX 75034 |
ELECT. CTR. | SORENSEN ELECTRIC | (972)578-9395 | SUSAN@SORENSENELECTRIC.COM | 1770 MILLARD SUITE D | PLANO, TX 75074 |
FIRE CONT 2 | Rescom Fire Systems | (214)538-7500 | | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | TEXENERGY SOLUTIONS | (972)579-2009 | SELLISON@TEXENERGY.ORG | 2611 E. PIONEER | IRVING, TX 75061 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)831-3950 | dripley@reliantac.com | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | RANGER PLUMBING LLC | (214)585-6632 | D2HILT@HOTMAIL.COM | 5209 BOBTOWN ROAD | GARLAND, TX 75043 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/17/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
10/18/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
10/3/2011
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/11/2017
| | 5/11/2017 | |
More Info
|
BACKFLOW | APPROVED |
9/30/2011
| | 9/30/2011 | |
More Info
|
BACKFLOW | APPROVED |
9/23/2011
| | 9/23/2011 | |
More Info
|
There are currently no reviews on this record.