Permit Info
Short Description:
3792 AC, 4162 SF, SFR / 2 STORY
Notes:
3792 AC, 4162 SF, SFR / 2 STORY
4/29/2011 12:00:00 AM
001. ENERGY STAR/GREEN BLDG/90 DAY DIRECTIVE EFF 04/01/2011.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
COBB FARM PH 2
|
BF TESTER | CHRIS JONES | (214)597-1760 | | 1931 MIDDLE GLEN DR | CARROLLTON, TX 75007 |
OWNER | BEAZER HOMES | (972)250-3821 | | 501 W. George Bush Hwy, #100 | Richardson, TX 75080 |
APPLICANT | BEAZER HOMES | (972)250-3821 | | 501 W. George Bush Hwy, #100 | Richardson, TX 75080 |
CONTRACTOR | BEAZER HOMES | (972)250-3821 | | 501 W. George Bush Hwy, #100 | Richardson, TX 75080 |
ELECT. CTR. | SORENSON ELECTRIC | (972)578-9395 | SUSAN@SORENSENELECTRIC.COM | 1770 MILLARD SUITE D | PLANO, TX 75074 |
HERS PROVIDE | BURGESS CONSTRUCTION CONSULTAN | (214)291-3141 | CBROOKS@BURGESS-INC.COM | 1255 W 15TH STE 100 | PLANO, TX 75075 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | CHERRI.GAINS@RESSERVICES.COM | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | 900 ALPHA #430 | RICHARDSON, TX 75081 |
STRUCT ENG | ERIC L. DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
9/15/2011
| | 9/15/2011 | |
More Info
|
There are currently no reviews on this record.