Permit Info
Short Description:
3367 AC, 4284 SF, SFR / 2 STORY
Notes:
3367 AC, 4284 SF, SFR / 2 STORY
5/3/2011 12:00:00 AM
(5/3/2011 10:46 AM JC)
001. ENERGY STAR/GREEN BLDG/90 DAY DIRECTIVE EFF 04/01/2011.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
027. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
031. SIDING DIRECTLY OVER MASONRY AT SECOND STORY IS NOT ALLOWED.
032. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
051. WINDOW BOX-OUTS MUST NOT EXCEED TWICE THE WINDOW M.O. AREA.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
(5/3/2011 10:47 AM JC)
Grade Beams : 10" w. x 22" d. (MFD)
2nd. story with a bonus room and bath.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
SHADDOCK CREEK ESTATES PH 4B
|
BF TESTER | EDWARD GANDARA | (972)671-3776 | | 3901 CLIFTON | RICHARDSON, TX 75082 |
OWNER | K HOVNANIAN HOMES | (469)737-1400 | bdavidson@khov.com | 5808 W. PLANO PKWY | PLANO, TX 75093 |
APPLICANT | K HOVNANIAN HOMES | (469)737-1400 | bdavidson@khov.com | 5808 W. PLANO PKWY | PLANO, TX 75093 |
CONTRACTOR | K HOVNANIAN HOMES | (469)737-1400 | bdavidson@khov.com | 5808 W. PLANO PKWY | PLANO, TX 75093 |
ELECT. CTR. | SWARTZ ELECTRIC | (972)254-3480 | SCHASE@SWARTZ-ELECTRIC-INC.COM | 228 IRBY LANE | IRVING, TX 75061 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | sshain@foxenergyspecialists.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | 2166 S JUPITER | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | 900 ALPHA #430 | RICHARDSON, TX 75081 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | SDICKSON@DE-STRUCTURES.COM | 100 N. CENTRAL EXPRESSWAY STE. | DALLAS, TX 75201 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
9/16/2011
| | 9/16/2011 | |
More Info
|