Permit Info
Short Description:
4813 AC, 5921 SF, SFR / 2 STORY
Notes:
4813 AC, 5921 SF, SFR / 2 STORY
3/24/2011 12:00:00 AM
(3/24/2011 8:12 AM JC)
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
028. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
(3/24/2011 8:12 AM JC)
(FWF)
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
PARK PLACE ESTATES PH1
|
| BF TESTER | KENNETH A CARTWRIGHT | (940)566-1971 | | 2022 KENDOLPH DR | DENTON, TX 76205 |
| OWNER | SUTTON, TRENT MICHAEL & SAMANT | ()- | LORI@SHADDOCKHOMES.COM | | FRISCO, TX 75034 |
| MAIL TO | HOMEOWNER | ()- | LORI@SHADDOCKHOMES.COM | | FRISCO, TX 75034 |
| APPLICANT | SHADDOCK HOMES, LTD | (469)241-9581 | LORI@SHADDOCKHOMES.COM | 2400 DALLAS PKWY, STE 560 | PLANO, TX 75093 |
| CONTRACTOR | SHADDOCK HOMES, LTD | (469)241-9581 | LORI@SHADDOCKHOMES.COM | 2400 DALLAS PKWY, STE 560 | PLANO, TX 75093 |
| ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
| HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | BRENT@STRANDSYSTEMS.COM | 6221 RIVERSIDE DRIVE #116 | IRVING, TX 75039 |
| MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | 2166 S JUPITER | GARLAND, TX 75041 |
| PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | 900 ALPHA #430 | RICHARDSON, TX 75081 |
| STRUCT ENG | LARRY SMITH ENGINEERING | (972)964-2161 | ARSMITH@LARRYSMITHENG.COM | 2115 TEAKWOOD LANE SUITE 450 | PLANO, TX 75075 |
| Total Fees |
|
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.