Permit Info
Short Description:
4367 AC, 5543 SF, SFR / 2 STORY
Notes:
4367 AC, 5543 SF, SFR / 2 STORY
5/26/2011 12:00:00 AM
(5/26/2011 2:51 PM JC)
001. ENERGY STAR/GREEN BLDG/90 DAY DIRECTIVE EFF 04/01/2011.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
031. SIDING DIRECTLY OVER MASONRY AT SECOND STORY IS NOT ALLOWED.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
055. FUEL BURNING APPLIANCE INSTALLATION MUST BE CODE COMPLIANT.
(5/26/2011 2:52 PM JC)
Max. driveway width at a street is 24'-0" per attached.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
STONELAKE ESTATES WEST #2 (CFR)
|
BF TESTER | MICHAEL S. BURKE | (972)980-3734 | | 6622 EASTVIEW | SACHSE, TX 75048 |
OWNER | ADURI PHANI & VALLI SRUJANA | ()- | AGUTIERREZ@FIRSTTEXASHOMES.COM | | FRISCO, TX 75035-0169 |
MAIL TO | HOMEOWNER | ()- | AGUTIERREZ@FIRSTTEXASHOMES.COM | | FRISCO, TX 75035-0169 |
APPLICANT | FIRST TEXAS HOMES | (214)613-3400 | AGUTIERREZ@FIRSTTEXASHOMES.COM | 500 CRESCENT CT STE 500 | DALLAS, TX 75201 |
CONTRACTOR | FIRST TEXAS HOMES | (214)613-3400 | AGUTIERREZ@FIRSTTEXASHOMES.COM | 500 CRESCENT CT STE 500 | DALLAS, TX 75201 |
ELECT. CTR. | IES RESIDENTIAL, INC | (972)562-7724 | BECKY.COLLIER@IES-CO.COM | 713 TOWER LANE SUITE A | MCKINNEY, TX 75069 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | INFORMATION@METROCODE.COM | 2630 W FREEWAY, SUITE 200 | FT WORTH, TX 76102 |
MECH. CTR. | STARN AIR | (214)221-1313 | STARNAIRINC@AOL.COM | 1802 RESERVE | GARLAND, TX 75042 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | chernandez@lsplumb.com | 707 E ARAPAHO RD STE 210 | RICHARDSON, 75081 |
STRUCT ENG | ERIC L. DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
8/22/2011
| | 8/22/2011 | |