Short Description:
IRRIGATION 5517 AC, 6844 SF, SFR / 2 STORY
Notes:
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
027. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
032. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
056. LETTERS OF ACCEPTANCE REQUIRED FROM BOTH ENGINEERS FOR CO.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
IRRIGATION 5517 AC, 6844 SF, SFR / 2 STORY
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
THE SHORES AT WATERSTONE PH 1
|
BF TESTER | EDWARD GANDARA | (972)671-3776 | | 3901 CLIFTON | RICHARDSON, TX 75082 |
OWNER | STMARTIN, DAVID A & SANDRA G T | ()- | DWOOD@WINDSORHOMES.TX.COM | | FRISCO, TX 75034 |
MAIL TO | HOMEOWNER | ()- | DWOOD@WINDSORHOMES.TX.COM | | FRISCO, TX 75034 |
APPLICANT | WINDSOR HOMES CUMBERLAND LLC | (214)522-4945 | DWOOD@WINDSORHOMES.TX.COM | 3838 OAK LAWN AVENUE #1212 | DALLAS, TX 75219 |
CONTRACTOR | WINDSOR HOMES CUMBERLAND LLC | (214)522-4945 | DWOOD@WINDSORHOMES.TX.COM | 3838 OAK LAWN AVENUE #1212 | DALLAS, TX 75219 |
ELECT. CTR. | C & B ELECTRIC | (972)790-0707 | | 225 GILBERT CIRCLE | GRAND PRAIRIE, TX 75050 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (817)871-1703 | | 906 W MCDERMOTT #116 | ALLEN, TX |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | ADVENT AIR CONDITIONING, INC | (972)221-4373 | MDOUGLAS@ADVENTAIR.COM | 500 S. KEALY | LEWISVILLE, TX 75057 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | chernandez@lsplumb.com | 707 E ARAPAHO RD STE 210 | RICHARDSON, 75081 |
STRUCT ENG | C & B ELECTRIC | (972)790-0707 | | 225 GILBERT CIRCLE | GRAND PRAIRIE, TX 75050 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|