Permit Info
Short Description:
1 BF FIRE PROT - 4937 AC, 6153 SF, SFR / 2 STORY
Expiration Date:
2/9/2019
Notes:
1 BF FIRE PROT - 4937 AC, 6153 SF, SFR / 2 STORY
3/23/2011 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
023. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.2ND FLOOR:3BR, 2BA, GAME, MEDIA EXERCISE, WET BAR, ATTIC STORAGE
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
DOMINION AT PANTHER CREEK #3 (CFR)
|
| BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
| OWNER | BURKHARDT RICHARD H & SARAH L | ()- | msibigtroth@darlinghomes.com | | FRISCO, TX 75035-8999 |
| MAIL TO | BURKHARDT RICHARD H & SARAH L | ()- | msibigtroth@darlinghomes.com | | FRISCO, TX 75035-8999 |
| APPLICANT | DARLING HOMES | (972)624-4100 | msibigtroth@darlinghomes.com | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
| CONTRACTOR | DARLING HOMES | (972)624-4100 | msibigtroth@darlinghomes.com | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
| ELECT. CTR. | IN CHARGE ELCTRICAL SERVICES L | (512)778-6240 | SETHROBINSON@IN-CHARGE-ELECTIC.COM | 3101 US HWY 183 | LIBERTY HILL, TX 78642 |
| FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | | PO Box 630806 | Irving, TX 75063 |
| HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | sshain@foxenergyspecialists.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
| MECH. CTR. | TEMPO MECHANICAL SERVICES | (972)579-2000 | DAVID.GANNON@TEMPOAIR.COM | 2611 E PIONEER DR | IRVING, TX 75061 |
| PLUM. CONT. | FRITZ PLUMBING | (972)335-3560 | THOMAS@FRITZPLUMBING.COM | 11109 FRISCO STREET | FRISCO, TX 75034 |
| STRUCT ENG | MLAW CONSULTANTS & ENGINEERS | (512)835-7000 | CDMARQUARDT@MLAWDFW.COM | 2804 LONGHORN BLVD | AUSTIN, TX 78758 |
|
| BACK FLOW FORM REVIEW |
$25.00
|
3/23/2018
|
| BACK FLOW FORM REVIEW |
$25.00
|
5/5/2017
|
| BACK FLOW FORM REVIEW |
$25.00
|
8/22/2011
|
| Total Fees |
|
Charged: $75.00
Balance Due: $0.00
|
|
| BACKFLOW | APPROVED |
3/20/2018
| | 3/20/2018 | |
More Info
|
| BACKFLOW | APPROVED |
5/5/2017
| | 5/5/2017 | |
More Info
|
| BACKFLOW | APPROVED |
2/9/2016
| | 2/9/2016 | |
More Info
|
| BACKFLOW | APPROVED |
8/22/2011
| | 8/22/2011 | |
More Info
|
| BACKFLOW | APPROVED |
8/8/2011
| | 8/8/2011 | |
More Info
|
There are currently no reviews on this record.