Permit Info
Short Description:
3508 AC, 4310 SF, SFR / 2 STORY
Notes:
3508 AC, 4310 SF, SFR / 2 STORY
3/24/2011 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
027. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
056. LETTERS OF ACCEPTANCE REQUIRED FROM BOTH ENGINEERS FOR CO.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
DOMINION AT PANTHER CREEK #2 (CFR)
|
BF TESTER | ROBERT W. HARVEY | (972)346-3999 | | 3793 PHEASANT RUN | CELINA, TX 75009 |
OWNER | DARLING HOMES | (972)624-4100 | msibigtroth@darlinghomes.com | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
APPLICANT | DARLING HOMES | (972)624-4100 | msibigtroth@darlinghomes.com | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
CONTRACTOR | DARLING HOMES | (972)624-4100 | msibigtroth@darlinghomes.com | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
ELECT. CTR. | IN CHARGE ELCTRICAL SERVICES L | (512)778-6240 | SETHROBINSON@IN-CHARGE-ELECTIC.COM | 3101 US HWY 183 | LIBERTY HILL, TX 78642 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | sshain@foxenergyspecialists.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | TEMPO MECHANICAL SERVICES | (972)579-2000 | DAVID.GANNON@TEMPOAIR.COM | 2611 E PIONEER DR | IRVING, TX 75061 |
OTHER | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
PLUM. CONT. | FRITZ PLUMBING | (972)335-3560 | THOMAS@FRITZPLUMBING.COM | 11109 FRISCO STREET | FRISCO, TX 75034 |
STRUCT ENG | MLAW CONSULTANTS & ENGINEERS | (512)835-7000 | CDMARQUARDT@MLAWDFW.COM | 2804 LONGHORN BLVD | AUSTIN, TX 78758 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
7/17/2011
| | 7/17/2011 | |
More Info
|
There are currently no reviews on this record.