Permit Info
Short Description:
3612 AC, 4605 SF, SFR / 1 STORY
Notes:
3612 AC, 4605 SF, SFR / 1 STORY
11/16/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2nd FLOOR: BONUS ROOM & BATH OPTION.
I have requested a revised plot plan with additional information for the record. (sample copy e-mailed)
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
NEWMAN VILLAGE PH ONE
|
BF TESTER | CHRIS JONES | (214)597-1760 | | 1931 MIDDLE GLEN DR | CARROLLTON, TX 75007 |
OWNER | M CHRISTOPHER CUSTOM HOMES | (214)675-9229 | DAN@MCHRISTOPHERANDCOMPANY.COM | 630 OAKMONT CT | FAIRVIEW, TX 75069 |
APPLICANT | M CHRISTOPHER CUSTOM HOMES | (214)675-9229 | DAN@MCHRISTOPHERANDCOMPANY.COM | 630 OAKMONT CT | FAIRVIEW, TX 75069 |
CONTRACTOR | M CHRISTOPHER CUSTOM HOMES | (214)675-9229 | DAN@MCHRISTOPHERANDCOMPANY.COM | 630 OAKMONT CT | FAIRVIEW, TX 75069 |
ELECT. CTR. | IES RESIDENTIAL, INC | (281)498-2212 | BRITT.CRIST@IES-CO.COM | 10203 MULA CIRCLE | STAFFORD, TX 77477 |
HERS PROVIDE | TEXENERGY SOLUTIONS | (972)579-2009 | SELLISON@TEXENERGY.ORG | 2611 E. PIONEER | IRVING, TX 75061 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)831-3950 | CHUCK@RELIANTAC.COM | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | 1322 CENTURY WAY | WYLIE, TX 75098 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
3/3/2011
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
2/23/2011
| | 2/23/2011 | |
More Info
|