Permit Info
Short Description:
4162 AC, 4798 SF, SFR / 2 STORY
Notes:
4162 AC, 4798 SF, SFR / 2 STORY
10/29/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
045. SIDEYARD SET-BACK ENCROACHMENT AT BOX-OUTS LIMITED TO 12".
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
055. FUEL BURNING APPLIANCE INSTALLATION MUST BE CODE COMPLIANT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
GRAYHAWK SECT II PH V
|
BF TESTER | CHRIS JONES | ()- | | | |
OWNER | FIRST TEXAS HOMES | (214)432-0350 | AGUTIERREZ@FIRSTTEXASHOMES.COM | 500 CRESCENT CT #350 | DALLAS, TX 75201 |
APPLICANT | FIRST TEXAS HOMES | (214)432-0350 | AGUTIERREZ@FIRSTTEXASHOMES.COM | 500 CRESCENT CT #350 | DALLAS, TX 75201 |
CONTRACTOR | FIRST TEXAS HOMES | (214)432-0350 | AGUTIERREZ@FIRSTTEXASHOMES.COM | 500 CRESCENT CT #350 | DALLAS, TX 75201 |
ELECT. CTR. | IES RESIDENTIAL, INC | (281)498-2212 | BRITT.CRIST@IES-CO.COM | 10203 MULA CIRCLE | STAFFORD, TX 77477 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | INFORMATION@METROCODE.COM | 2630 W FREEWAY, SUITE 200 | FT WORTH, TX 76102 |
MECH. CTR. | STARN AIR | (214)221-1313 | STARNAIRINC@AOL.COM | 1802 RESERVE | GARLAND, TX 75042 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | chernandez@lsplumb.com | 707 E ARAPAHO RD STE 210 | RICHARDSON, 75081 |
STRUCT ENG | ERIC L. DAVIS ENGINEERING, INC | (972)564-0592 | ERICDAVIS@ELDENGINEERING.COM | P.O. BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/28/2011
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
1/17/2011
| | 1/17/2011 | |
More Info
|
There are currently no reviews on this record.