Permit Info
Short Description:
4709 AC, 5885 SF, SFR / 2 STORY
Expiration Date:
1/25/2012
Notes:
4709 AC, 5885 SF, SFR / 2 STORY
8/17/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. BEAMS=8"W X 30"D.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
VILLAGES OF STONELAKE ESTATES #1B (CFR)
|
BF TESTER | HAYDON M FURR | (214)585-6406 | | 7101 VIRGINIA PKWY APT 521 | MC KINNEY, TX 75071 |
OWNER | DREES CUSTOM HOMES | (972)953-4500 | PLEWIS@DREESHOMES.COM | 6225 SH 161 STE #400 | IRVING, TX 75038 |
MAIL TO | HOMEOWNER | ()- | | 15267 NOTTINGHAM | FRISCO, TX 75034 |
APPLICANT | DREES CUSTOM HOMES | (972)953-4500 | PLEWIS@DREESHOMES.COM | 6225 SH 161 STE #400 | IRVING, TX 75038 |
CONTRACTOR | DREES CUSTOM HOMES | (972)953-4500 | PLEWIS@DREESHOMES.COM | 6225 SH 161 STE #400 | IRVING, TX 75038 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | RESIDENTALSERVICE@FOXELECTRIC.COM | PO BOX 13338 | ARLINGTON, TX 76094 |
HERS PROVIDE | EIC, INC./COMFORT HOME | (972)485-4722 | CSIMPSON@COMFORTHOME.COM | 102 N. SHILOH ROAD #310 | GARLAND, TX 75042 |
MECH. CTR. | FRYMIRE ENGINEERING | (972)620-3500 | | 2818 SATSUMA | DALLAS, TX 75226 |
PLUM. CONT. | LASITER & LASITER PLUMBING | (817)831-4245 | SHANNONB@LASITER.COM | P.O. BOX 14638 | HALTOM CITY, TX 76117 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | TAMI@STRANDSYSTEMS.COM | 2964 LBJ FREEWAY # 312 | DALLAS, TX 75234 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/25/2011
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
1/25/2011
| | 1/25/2011 | |
More Info
|
There are currently no reviews on this record.