Short Description:
3998 AC, 5055 SF, SFR / 2 STORY
Expiration Date:
1/17/2012
Notes:
3998 AC, 5055 SF, SFR / 2 STORY
9/3/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
032. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
056. LETTERS OF ACCEPTANCE REQUIRED FROM BOTH ENGINEERS FOR CO.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
DOMINION AT PANTHER CREEK #3 (CFR)
|
| BF TESTER | ROBERT W. HARVEY | (972)346-3999 | | 3793 PHEASANT RUN | CELINA, TX 75009 |
| OWNER | DARLING HOMES | (972)624-4100 | CSCHRAMME@DARLINGHOMES.COM | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
| MAIL TO | HOMEOWNER | ()- | | 12501 TROLLEY DR | FRISCO, TX |
| APPLICANT | DARLING HOMES | (972)624-4100 | CSCHRAMME@DARLINGHOMES.COM | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
| CONTRACTOR | DARLING HOMES | (972)624-4100 | CSCHRAMME@DARLINGHOMES.COM | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
| ELECT. CTR. | IN CHARGE ELCTRICAL SERVICES L | (512)778-6240 | SETHROBINSON@IN-CHARGE-ELECTIC.COM | 3101 US HWY 183 | LIBERTY HILL, TX 78642 |
| HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
| MECH. CTR. | FRYMIRE ENGINEERING | (972)620-3500 | | 2818 SATSUMA | DALLAS, TX 75226 |
| PLUM. CONT. | FRITZ PLUMBING | (972)335-3560 | THOMAS@FRITZPLUMBING.COM | 11109 FRISCO ST | FRISCO, TX 75034 |
| STRUCT ENG | MLAW CONSULTANTS & ENGINEERS | (512)835-7000 | | 2804 LONGHORN BLVD | AUSTIN, TX 78758 |
|
| BACK FLOW FORM REVIEW |
$25.00
|
1/24/2011
|
| Total Fees |
|
Charged: $25.00
Balance Due: $0.00
|
|
| BACKFLOW | APPROVED |
1/17/2011
| | 1/17/2011 | |
More Info
|