Permit Info
Short Description:
4741 AC, 5236 SF, SFR / 2 STORY
Expiration Date:
1/17/2012
Notes:
4741 AC, 5236 SF, SFR / 2 STORY
8/11/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. BEAMS=8"W X 30"D.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
CROWN RIDGE #2 (CFR)
|
BF TESTER | BRIAN MCDONALD | (940)634-2234 | | 219 COMANCHE DR | LAKE KIOWA, TX 76240 |
OWNER | GRAND HOMES | (972)387-6037 | LDYE@GRANDHOMES.COM | 15950 N DALLAS PKY #600 | DALLAS, TX 75248 |
MAIL TO | HOMEOWNER | ()- | | 13904 MIRANDA | FRISCO, TX 75034 |
APPLICANT | GRAND HOMES | (972)387-6037 | LDYE@GRANDHOMES.COM | 15950 N DALLAS PKY #600 | DALLAS, TX 75248 |
CONTRACTOR | GRAND HOMES | (972)387-6037 | LDYE@GRANDHOMES.COM | 15950 N DALLAS PKY #600 | DALLAS, TX 75248 |
ELECT. CTR. | IES RESIDENTIAL, INC | (281)498-2212 | BRITT.CRIST@IES-CO.COM | 10203 MULA CIRCLE | STAFFORD, TX 77477 |
HERS PROVIDE | ACP ALLIED CONSTRUCTION PROFES | (214)227-9540 | TONYA@ENERGYACP.COM | 1900 ESPINOSA DRIVE | Carrollton, TX 75010 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | CHERRI.GAINS@RESSERVICES.COM | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | TEXAS UNITED EXCAVATORS | (972)446-2500 | DIANA@TUEXCAVATORS.COM | 1451 HALSEY WAY | CARROLLTON, TX 75007 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | TAMI@STRANDSYSTEMS.COM | 2964 LBJ FREEWAY # 312 | DALLAS, TX 75234 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/21/2011
|
BACK FLOW FORM REVIEW |
$25.00
|
1/21/2011
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
There are currently no reviews on this record.