Permit Info
Short Description:
3597 AC, 4648 SF, SFR / 1 STORY
Approved Date:
12/17/2010
Notes:
3597 AC, 4648 SF, SFR / 1 STORY
8/4/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
012. BEAMS=10"W X 30"D.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
053. SEE THE ENCLOSED ONE (1) HOUR FIREWALL DESIGN SKETCH.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
NEWMAN VILLAGE PH ONE
|
BF TESTER | ROBERT W. HARVEY | (972)346-3999 | | 3793 PHEASANT RUN | CELINA, TX 75009 |
OWNER | DARLING HOMES | (972)624-4100 | CSCHRAMME@DARLINGHOMES.COM | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
APPLICANT | DARLING HOMES | (972)624-4100 | CSCHRAMME@DARLINGHOMES.COM | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
CONTRACTOR | DARLING HOMES | (972)624-4100 | CSCHRAMME@DARLINGHOMES.COM | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | RESIDENTALSERVICE@FOXELECTRIC.COM | PO BOX 13338 | ARLINGTON, TX 76094 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | TEMPO MECHANICAL SERVICES | (972)579-2000 | DAVID.GANNON@TEMPOAIR.COM | 2611 E PIONEER DR | IRVING, TX 75061 |
PLUM. CONT. | FRITZ PLUMBING | (972)335-3560 | THOMAS@FRITZPLUMBING.COM | 11109 FRISCO ST | FRISCO, TX 75034 |
STRUCT ENG | MLAW CONSULTANTS & ENGINEERS | (512)835-7000 | | 2804 LONGHORN BLVD | AUSTIN, TX 78758 |
|
BACK FLOW FORM REVIEW |
$25.00
|
12/27/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
12/17/2010
| | 12/17/2010 | |
More Info
|