Permit Info
Short Description:
4448 AC, 5143 SF, SFR / 2 STORY
Approved Date:
11/22/2010
Expiration Date:
11/22/2011
Notes:
4448 AC, 5143 SF, SFR / 2 STORY
6/15/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2nd FLOOR: 3-BED ROOMS, 2-BATHSA,TECH. CTR., GAME ANDMEDIA ROOMS WITH A WET BAR.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
PEARSON FARMS 1A
|
BF TESTER | EDWARD GANADRA | (972)671-3776 | | 3901 CLIFTON | RICHARDSON, TX 75082 |
OWNER | SHADDOCK HOMES, LTD | (469)241-9581 | LORI@SHADDOCKHOMES.COM | 2400 DALLAS PKWY, STE 560 | PLANO, TX 75093 |
MAIL TO | HOMEOWNER | ()- | | 2843 ENCLAVE DR | FRISCO, TX 75034 |
APPLICANT | SHADDOCK HOMES, LTD | (469)241-9581 | LORI@SHADDOCKHOMES.COM | 2400 DALLAS PKWY, STE 560 | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES, LTD | (469)241-9581 | LORI@SHADDOCKHOMES.COM | 2400 DALLAS PKWY, STE 560 | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | KRUGER & SON HEATING & AIR | (972)271-9319 | | 2166 S JUPITER | GARLAND, TX 75041 |
PLUM. CONT. | RANGER PLUMBING LLC | (214)585-6632 | D2HILT@HOTMAIL.COM | 5209 BOBTOWN ROAD | GARLAND, TX 75043 |
STRUCT ENG | LARRY SMITH ENGINEERING | (972)964-2161 | ARSMITH@LARRYSMITHENG.COM - ADRIA | 2115 TEAKWOOD LANE SUITE 450 | PLANO, TX 75075 |
|
BACK FLOW FORM REVIEW |
$25.00
|
11/23/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
11/20/2010
| | 11/20/2010 | |
More Info
|
There are currently no reviews on this record.