Permit Info
Short Description:
3278 AC, 4166 SF, SFR / 2 STORY
Notes:
3278 AC, 4166 SF, SFR / 2 STORY
8/5/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
VILLAGES OF STONELAKE ESTATES #1C (CFR)
|
BF TESTER | DALLAS DICKERSON | (972)562-0342 | | 560 PALOMINO DR | LUCAS, TX 75002 |
OWNER | HIGHLAND HOMES | (972)789-3500 | | 12850 HILLCREST STE 20-0 | DALLAS, TX 75230 |
APPLICANT | HIGHLAND HOMES | (972)789-3500 | | 12850 HILLCREST STE 20-0 | DALLAS, TX 75230 |
CONTRACTOR | HIGHLAND HOMES | (972)789-3500 | | 12850 HILLCREST STE 20-0 | DALLAS, TX 75230 |
ELECT. CTR. | FUSION ELECTRIC LLC | (972)347-2387 | FUSELEC@SBCGLOBAL.NET | P.O. BOX 936 | PROSPER, TX 75078 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | 128 FAIRVIEW | ARLINGTON, TX 76010 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | DGUGLIOTTA@LSPLUMB.COM | 707 E ARAPAHO RD STE 210 | RICHARDSON, 75081 |
STRUCT ENG | ERIC L. DAVIS ENGINEERING, INC | (972)564-0592 | ERICDAVIS@ELDENGINEERING.COM | P.O. BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
11/5/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
11/3/2010
| | 11/3/2010 | |
More Info
|
There are currently no reviews on this record.