Permit Info
Short Description:
4557 AC, 5644 SF, SFR / 2 STORY
Approved Date:
10/27/2010
Notes:
4557 AC, 5644 SF, SFR / 2 STORY
7/7/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
SHADDOCK CREEK ESTATES PH 5
|
BF TESTER | MIKE JOHNSON | (972)442-2594 | | 2418 DARKSIDE | GARLAND, TX 75040 |
OWNER | MEGATEL HOMES INC | (972)339-0159 | AARON@MEGATELHOMES.COM | 3308 PRESTON RD # 350-190 | PLANO, TX 75093 |
APPLICANT | MEGATEL HOMES INC | (972)339-0159 | AARON@MEGATELHOMES.COM | 3308 PRESTON RD # 350-190 | PLANO, TX 75093 |
CONTRACTOR | MEGATEL HOMES INC | (972)339-0159 | AARON@MEGATELHOMES.COM | 3308 PRESTON RD # 350-190 | PLANO, TX 75093 |
ELECT. CTR. | IES RESIDENTIAL, INC | (281)498-2212 | BRITT.CRIST@IES-CO.COM | 10203 MULA CIRCLE | STAFFORD, TX 77477 |
HERS PROVIDE | TRUE HOME ENERGY SOLUTIONS | (972)575-8320 | | PO BOX 2644 | WYLIE, TX 75098 |
MECH. CTR. | LONGHORN HT'G & A/C | (972)475-0009 | SERVICE@LONGHORNHVAC.COM | 4831 GRISHAM | ROWLETT, TX 75088 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | 1322 CENTURY WAY | WYLIE, TX 75098 |
STRUCT ENG | ERIC L. DAVIS ENGINEERING, INC | (972)564-0592 | ERICDAVIS@ELDENGINEERING.COM | P.O. BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
11/3/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/27/2010
| | 10/27/2010 | |
More Info
|
There are currently no reviews on this record.