Permit Info
Short Description:
3515 AC, 4300 SF, SFR / 2 STORY
Approved Date:
10/22/2010
Notes:
3515 AC, 4300 SF, SFR / 2 STORY
6/15/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
012. BEAMS=10"W X 30"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
028. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
3-BED ROOMS, 2-BATHS, GAME & MEDIA ROOMS.
(09/22/2010 10:39 AM DMC)
REGISTER WAS OFF METER PER METERS/ADAM R. ON 09-03-10.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
SHADDOCK CREEK ESTATES PH 4B
|
BF TESTER | JOSHUA M. SHIELDS | (972)242-2229 | | 1730 SANFRANCICO ST | CARROLLTON, TX 75007 |
OWNER | SHADDOCK & MCNAUGHT LLC | (972)378-3972 | | 5900 W PARKER ROAD STE 278-193 | PLANO, TX 75093 |
APPLICANT | SHADDOCK & MCNAUGHT LLC | (972)378-3972 | | 5900 W PARKER ROAD STE 278-193 | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK & MCNAUGHT LLC | (972)378-3972 | | 5900 W PARKER ROAD STE 278-193 | PLANO, TX 75093 |
ELECT. CTR. | GALAXY ELECTRIC INC | (469)682-1375 | | 309 N GALLOWAY | MESQUITE, TX 75149 |
MECH. CTR. | KRUGER & SON HEATING & AIR | (972)271-9319 | | 2166 S JUPITER | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | JOE@ENTERPRISE.COM | 900 ALPHA #430 | RICHARDSON, TX 75081 |
STRUCT ENG | PARAGON STRUCTURAL ENGINEERING | (214)477-4737 | BRIAN@PSEGLOBAL.COM | 7148 SILVERBROOK LN | Frisco, Tx 75034 |
|
BACK FLOW FORM REVIEW |
$25.00
|
10/22/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/22/2010
| | 10/22/2010 | |