Short Description:
NO BF FIRE PROT - 5029 AC, 6000 SF, SFR / 2 STORY
Notes:
NO BF FIRE PROT - 5029 AC, 6000 SF, SFR / 2 STORY
5/10/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
012. BEAMS=10"W X 30"D.
021. W/12" DIA. PIERS W/(2) #5 REBAR.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
GRIFFIN PARC PH 4
|
OWNER | MICHAELS, MATTHEW C & CORINNE | ()- | | | FRISCO, TX 75033 |
MAIL TO | MICHAELS, MATTHEW C & CORINNE | ()- | | | FRISCO, TX 75033 |
APPLICANT | JPA DEVELOPMENT CORPORATION | (972)333-6407 | | 5729 LEBANON DR #144-201 | FRISCO, TX 75034 |
CONTRACTOR | JPA DEVELOPMENT CORPORATION | (972)333-6407 | | 5729 LEBANON DR #144-201 | FRISCO, TX 75034 |
ELECT. CTR. | ARI-TEX ELECTRIC INC | (972)727-9902 | SERVICECARI-TEX.COM | 606 CENTRAL EXPRESSWAY | ALLEN, TX 75013 |
MECH. CTR. | KRUGER & SON HEATING & AIR | (972)271-9319 | | 2166 S JUPITER | GARLAND, TX 75041 |
PLUM. CONT. | RANGER PLUMBING LLC | (214)585-6632 | D2HILT@HOTMAIL.COM | 5209 BOBTOWN ROAD | GARLAND, TX 75043 |
STRUCT ENG | PARAGON STRUCTURAL ENGINEERING | (214)477-4737 | BRIAN@PSEGLOBAL.COM | 7148 SILVERBROOK LN | Frisco, Tx 75034 |
|
BACK FLOW FORM REVIEW |
$25.00
|
10/12/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
There are currently no inspections on this record.
There are currently no reviews on this record.