Permit Info
Short Description:
3189 AC, 3897 SF, SFR / 2 STORY
Notes:
3189 AC, 3897 SF, SFR / 2 STORY
5/6/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 22"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
032. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2nd FLOOR: 1-BED ROOM, 1-BATH AND BONUS ROOM.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
CROWN RIDGE #1A (CFR)
|
BF TESTER | EDWARD GANADRA | (972)671-3776 | | 3901 CLIFTON | RICHARDSON, TX 75082 |
OWNER | K HOVNANIAN HOMES | (469)737-1400 | | 5808 W. PLANO PKWY | PLANO, TX 75093 |
APPLICANT | K HOVNANIAN HOMES | (469)737-1400 | | 5808 W. PLANO PKWY | PLANO, TX 75093 |
CONTRACTOR | K HOVNANIAN HOMES | (469)737-1400 | | 5808 W. PLANO PKWY | PLANO, TX 75093 |
ELECT. CTR. | SWARTZ ELECTRIC | (972)254-3480 | SCHASE@SWARTZ-ELECTRIC-INC.COM | 228 IRBY LANE | IRVING, TX 75061 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | KRUGERS HEAT'G & A/C | (972)276-4566 | | 1409 S JUPITER RD | GARLAND, TX 75042 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | JOE@ENTERPRISE.COM | 900 ALPHA #430 | RICHARDSON, TX 75081 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | SDICKSON@DE-STRUCTURES.COM | 100 N. CENTRAL EXPRESSWAY STE. | DALLAS, TX 75201 |
|
BACK FLOW FORM REVIEW |
$25.00
|
9/20/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
9/14/2010
| | 9/14/2010 | |
More Info
|
There are currently no reviews on this record.