Permit Info
Short Description:
3506 AC, 4093 SF, SFR / 2 STORY
Notes:
3506 AC, 4093 SF, SFR / 2 STORY
6/2/2010 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
030. 1ST FLOOR WINDOW BOX-OUTS MUST HAVE MASONRY BELOW.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
051. WINDOW BOX-OUTS MUST NOT EXCEED TWICE THE WINDOW M.O. AREA.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
(6/14/2010 2:13 PM VI)
BUILDER HAS AGREED TO REDUCE THE PORCH DIMENSION FRONT TO STUDS TO FIT THE FRONT B.L.
Parcel Info
City/State/Zip:
FRISCO, TX, 75070
Subdivision:
PANTHER CREEK ESTATES #2 (CFR)
|
BF TESTER | MIKE JOHNSON | (972)442-2594 | | 2418 DARKSIDE | GARLAND, TX 75040 |
OWNER | MERITAGE HOMES | (972)580-6300 | MELISSA.GAJEWSKI@MERITAGEHOMES.COM | 909 HIDDEN RIDGE #400 | IRVING, TX 75038 |
APPLICANT | MERITAGE HOMES | (972)580-6300 | MELISSA.GAJEWSKI@MERITAGEHOMES.COM | 909 HIDDEN RIDGE #400 | IRVING, TX 75038 |
CONTRACTOR | MERITAGE HOMES | (972)580-6300 | MELISSA.GAJEWSKI@MERITAGEHOMES.COM | 909 HIDDEN RIDGE #400 | IRVING, TX 75038 |
ELECT. CTR. | C & B ELECTRIC | (972)790-0707 | | 225 GILBERT CIRCLE | GRAND PRAIRIE, TX 75050 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | CHERRI.GAINS@RESSERVICES.COM | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | DGUGLIOTTA@LSPLUMB.COM | 707 E ARAPAHO RD STE 210 | RICHARDSON, 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
9/3/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
8/27/2010
| | 8/27/2010 | |
More Info
|
There are currently no reviews on this record.