Permit Info
Short Description:
1 bf water soft 2624 AC, 3229 SF, SFR / 2 STORY
Expiration Date:
9/20/2018
Notes:
1 bf water soft 2624 AC, 3229 SF, SFR / 2 STORY
5/27/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
012. BEAMS=10"W X 30"D.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
GRAYHAWK SEC II PH IV
|
BF TESTER | CHRIS JONES | (214)597-1760 | chrisjonesbackflow@gmail.com | 1931 MIDDLE GLEN DR | CARROLLTON, TX 75007 |
OWNER | THULLURI, RADHIKA & VEERALENIN | ()- | | | FRISCO, TX 75033-0468 |
MAIL TO | THULLURI, RADHIKA & VEERALENIN | ()- | | | FRISCO, TX 75033-0468 |
APPLICANT | FIRST TEXAS HOMES | (214)432-0350 | AGUTIERREZ@FIRSTTEXASHOMES.COM | 500 CRESCENT CT #350 | DALLAS, TX 75201 |
CONTRACTOR | FIRST TEXAS HOMES | (214)432-0350 | AGUTIERREZ@FIRSTTEXASHOMES.COM | 500 CRESCENT CT #350 | DALLAS, TX 75201 |
ELECT. CTR. | IES RESIDENTIAL, INC | (281)498-2212 | BRITT.CRIST@IES-CO.COM | 10203 MULA CIRCLE | STAFFORD, TX 77477 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | INFORMATION@METROCODE.COM | 2630 W FREEWAY, SUITE 200 | FT WORTH, TX 76102 |
MECH. CTR. | STARN AIR | (214)221-1313 | STARNAIRINC@AOL.COM | 1802 RESERVE | GARLAND, TX 75042 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | DGUGLIOTTA@LSPLUMB.COM | 707 E ARAPAHO RD STE 210 | RICHARDSON, 75081 |
STRUCT ENG | ERIC L. DAVIS ENGINEERING, INC | (972)564-0592 | ERICDAVIS@ELDENGINEERING.COM | P.O. BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
8/31/2010
|
BACK FLOW FORM REVIEW |
$25.00
|
9/27/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
9/26/2017
| | 9/26/2017 | |
More Info
|
BACKFLOW | APPROVED |
8/29/2010
| | 8/29/2010 | |
More Info
|
There are currently no reviews on this record.