Permit Info
Short Description:
1 BF FIRE PROT - 5443 AC, 7192 SF, SFR / 2 STORY
Expiration Date:
8/4/2018
Notes:
1 BF FIRE PROT - 5443 AC, 7192 SF, SFR / 2 STORY
4/21/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
020. W/12" DIA. PIERS W/(1) #5 REBAR.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
PARK PLACE ESTATES PH1
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | CHALMERS, MATTHEW & LULWA | ()- | LORI@SHADDOCKHOMES.COM | | FRISCO, TX 75034 |
MAIL TO | CHALMERS, MATTHEW & LULWA | ()- | LORI@SHADDOCKHOMES.COM | | FRISCO, TX 75034 |
APPLICANT | SHADDOCK HOMES, LTD | (469)241-9581 | LORI@SHADDOCKHOMES.COM | 2400 DALLAS PKWY, STE 560 | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES, LTD | (469)241-9581 | LORI@SHADDOCKHOMES.COM | 2400 DALLAS PKWY, STE 560 | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
FIRE CONTACT | Rescom Fire Systems | (214)350-1755 | | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | KRUGER & SON HEATING & AIR | (972)271-9319 | | 2166 S JUPITER | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | JOE@ENTERPRISE.COM | 900 ALPHA #430 | RICHARDSON, TX 75081 |
STRUCT ENG | LARRY SMITH ENGINEERING | (972)964-2161 | ARSMITH@LARRYSMITHENG.COM - ADRIA | 2115 TEAKWOOD LANE SUITE 450 | PLANO, TX 75075 |
|
BACK FLOW FORM REVIEW |
$25.00
|
8/20/2010
|
BACK FLOW FORM REVIEW |
$25.00
|
10/5/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
8/17/2016
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|