Permit Info
Short Description:
3588 AC, 4447 SF, SFR / 2 STORY
Notes:
3588 AC, 4447 SF, SFR / 2 STORY
3/3/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
031. SIDING DIRECTLY OVER MASONRY AT SECOND STORY IS NOT ALLOWED.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
Parcel Info
City/State/Zip:
FRISCO, TX, 75036
Subdivision:
STONEWATER CROSSING PHASE ONE
|
BF TESTER | JAMES P WILLIS | (214)909-7822 | | 9092 BRUSHY CREEK TRAIL | FT. WORTH, TX 76118 |
OWNER | AMERICAN LEGEND HOMES | (972)410-5701 | NADER.BAHA@ALHLTD.COM | 2540 KING ARTHUR BLVD #222 | LEWISVILLE, TX 75056 |
APPLICANT | AMERICAN LEGEND HOMES | (972)410-5701 | NADER.BAHA@ALHLTD.COM | 2540 KING ARTHUR BLVD #222 | LEWISVILLE, TX 75056 |
CONTRACTOR | AMERICAN LEGEND HOMES | (972)410-5701 | NADER.BAHA@ALHLTD.COM | 2540 KING ARTHUR BLVD #222 | LEWISVILLE, TX 75056 |
ELECT. CTR. | C & B ELECTRIC | (972)790-0707 | | 225 GILBERT CIRCLE | GRAND PRAIRIE, TX 75050 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | ct@nelrod.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | 128 FAIRVIEW | ARLINGTON, TX 76010 |
PLUM. CONT. | LASITER & LASITER PLUMBING | (817)831-4245 | SHANNONB@LASITER.COM | P.O. BOX 14638 | HALTOM CITY, TX 76117 |
STRUCT ENG | ERIC L. DAVIS ENGINEERING, INC | (972)564-0592 | ERICDAVIS@ELDENGINEERING.COM | P.O. BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/29/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
6/15/2010
| | 6/15/2010 | |
More Info
|
There are currently no reviews on this record.