Permit Info
Short Description:
1 BF--FIRE 4988 AC, 7318 SF, SFR / 2 STORY (BF-FIRE)
Status:
RES LETTER TWO SENT
Expiration Date:
4/27/2018
Notes:
1 BF--FIRE 4988 AC, 7318 SF, SFR / 2 STORY (BF-FIRE)
3/24/2008 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
12. BEAMS=10"W X 30"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR.
26. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
35. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
36. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
37. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
42. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
50. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034-6933
Subdivision:
STONEBRIAR COUNTRY CLUB ESTATES
|
BF TESTER | JEFFREY WORLEY | (972)699-7156 | | 1662 CR 1020 | RAVENNA, TX 75476 |
OWNER | POPE, TERRY DEAN & BARBARA ALY | ()- | | | FRISCO, TX 75034 |
MAIL TO | POPE, TERRY DEAN & BARBARA ALY | ()- | | | FRISCO, TX 75034 |
APPLICANT | SHELLEY MALONE CUST BLD | (214)676-7907 | | 7800 PRESTON RD #153 | PLANO, TX 75024 |
CONTRACTOR | SHELLEY MALONE CUST BLD | (214)676-7907 | | 7800 PRESTON RD #153 | PLANO, TX 75024 |
ELECT. CTR. | MEGA ELECTRIC CO., INC. | (972)727-8263 | MEGAELECTRICAL@AOL.COM | P.O. BOX 757 | ALLEN, TX 75013 |
HERS PROVIDE | METRO CODE ANALYSIS X 04/2008 | (817)335-1497 | INFORMATION@METROCODE.COM | 2630 W FREEWAY, SUITE 200 | FT WORTH, TX 76102 |
MECH. CTR. | ENVIRONMENTAL CONTROLS X-05/20 | (972)219-9982 | | PO BOX 292204 | LEWISVILLE, TX 75029 |
PLUM. CONT. | OLD TOWN PLUMBING CO LLC X-03 | (972)353-3984 | | 1509 MARBLEHEAD | LEWISVILLE, TX 75067 |
STRUCT ENG | PARAGON STRUCTURAL ENGINEERING | (214)941-8350 | brian@pseglobal.com | 5068 W PLANO PKWY, SUITE 199 | PLANO, TX 75093 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/23/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
6/16/2017
| | 6/16/2017 | |
More Info
|
BACKFLOW | APPROVED |
4/27/2009
| | 4/27/2009 | |
More Info
|
There are currently no reviews on this record.